Lens Distance Calculator
Choose one of the common 1/2.8-inch sensors or enter your camera’s horizontal pixels and pixel size. The calculator shows how far away a person can be for each level of detail, plus the pixel density at your own target distance.
Lens Distance Chart by Resolution
Maximum distance for each IEC 62676-4 level, calculated with the formula below. Sensor sizes come from the Sony IMX327, IMX335, and IMX415 datasheets, three common 1/2.8-inch security camera sensors. Pixel densities are from the Axis IEC 62676-4 white paper.
2 MP (1920 × 1080), 1/2.8-inch, 2.9 µm
| Lens | Horizontal FOV | Detect | Observe | Recognize | Identify |
|---|---|---|---|---|---|
| 2.8 mm | 90° | 127 ft (38.6 m) | 50 ft (15.3 m) | 25 ft (7.7 m) | 13 ft (3.9 m) |
| 4 mm | 70° | 181 ft (55.2 m) | 72 ft (21.9 m) | 36 ft (11.0 m) | 18 ft (5.5 m) |
| 6 mm | 50° | 272 ft (82.8 m) | 108 ft (32.8 m) | 54 ft (16.6 m) | 27 ft (8.3 m) |
| 8 mm | 38° | 362 ft (110.3 m) | 144 ft (43.8 m) | 72 ft (22.1 m) | 36 ft (11.0 m) |
| 12 mm | 26° | 543 ft (165.5 m) | 215 ft (65.7 m) | 109 ft (33.1 m) | 54 ft (16.6 m) |
5 MP (2592 × 1944), 1/2.8-inch, 2.0 µm
| Lens | Horizontal FOV | Detect | Observe | Recognize | Identify |
|---|---|---|---|---|---|
| 2.8 mm | 86° | 184 ft (56.0 m) | 73 ft (22.2 m) | 37 ft (11.2 m) | 18 ft (5.6 m) |
| 4 mm | 66° | 262 ft (80.0 m) | 104 ft (31.7 m) | 52 ft (16.0 m) | 26 ft (8.0 m) |
| 6 mm | 47° | 394 ft (120.0 m) | 156 ft (47.6 m) | 79 ft (24.0 m) | 39 ft (12.0 m) |
| 8 mm | 36° | 525 ft (160.0 m) | 208 ft (63.5 m) | 105 ft (32.0 m) | 52 ft (16.0 m) |
| 12 mm | 24° | 787 ft (240.0 m) | 312 ft (95.2 m) | 157 ft (48.0 m) | 79 ft (24.0 m) |
8 MP / 4K (3840 × 2160), 1/2.8-inch, 1.45 µm
| Lens | Horizontal FOV | Detect | Observe | Recognize | Identify |
|---|---|---|---|---|---|
| 2.8 mm | 90° | 253 ft (77.2 m) | 101 ft (30.7 m) | 51 ft (15.4 m) | 25 ft (7.7 m) |
| 4 mm | 70° | 362 ft (110.3 m) | 144 ft (43.8 m) | 72 ft (22.1 m) | 36 ft (11.0 m) |
| 6 mm | 50° | 543 ft (165.5 m) | 215 ft (65.7 m) | 109 ft (33.1 m) | 54 ft (16.6 m) |
| 8 mm | 38° | 724 ft (220.7 m) | 287 ft (87.6 m) | 145 ft (44.1 m) | 72 ft (22.1 m) |
| 12 mm | 26° | 1,086 ft (331.0 m) | 431 ft (131.4 m) | 217 ft (66.2 m) | 109 ft (33.1 m) |
Doubling the focal length or the horizontal pixels doubles every distance in the chart.
DORI Pixel Density Levels
IEC 62676-4:2014 defines four operational requirements. The values below are from the Axis white paper, based on an average face width of 16 cm (6 5/16 in). The px/ft values are the precise conversions Axis uses in datasheets; rounded values of 20, 40, and 80 px/ft are also common.
| Level | Pixels per meter | Pixels per foot | Pixels across a face |
|---|---|---|---|
| Detect | 25 px/m | 8 px/ft | 4 px |
| Observe | 63 px/m | 19 px/ft | 10 px |
| Recognize | 125 px/m | 38 px/ft | 20 px |
| Identify | 250 px/m | 76 px/ft | 40 px |
How the Calculator Works
sensor width (mm) = horizontal pixels × pixel size (µm) ÷ 1000
max distance (m) = horizontal pixels × focal length ÷ (sensor width × required px/m)
horizontal FOV = 2 × atan(sensor width ÷ (2 × focal length))
This is the pinhole lens model: scene width at a distance equals distance × sensor width ÷ focal length, and pixel density is horizontal pixels ÷ scene width. Example: a 2 MP sensor is 1920 × 2.9 µm = 5.57 mm wide, so with a 2.8 mm lens detection (25 px/m) reaches 1920 × 2.8 ÷ (5.57 × 25) = 38.6 m, or 127 ft.
As a cross-check, the AXIS P1385 datasheet (1/2.8-inch, 2.9 µm, 1920 × 1080, 2.8 mm wide end) lists 38.8 m detect, 15.4 m observe, 7.7 m recognize, and 3.9 m identify; this calculator gives 38.6, 15.3, 7.7, and 3.9 m. At the 13 mm tele end, the datasheet values are lower than the pinhole model because Axis includes lens distortion.
Limits and Planning Tips
The distances apply at the center of the image. Axis notes that pixel density varies across the image, and that motion, compression, lighting, and focus affect whether a person can actually be recognized or identified, so use margins when planning (AXIS P1385 datasheet).
Night performance is a separate limit: a camera’s IR range can be shorter than its detection distance. Wide-angle lenses with strong barrel distortion also give a wider real field of view than the formula, with fewer pixels per meter at the edges.
The newer IEC 62676-4:2025 edition replaces DORI with seven levels from Overview (20 px/m) to Scrutinize (1500 px/m), per the Axis 2025 white paper. Recognize at 125 px/m and Identify at 250 px/m match its Perceive and Characterize levels.
Comparing camera resolutions? See the security camera resolution comparison, and size the recorder with the NVR storage calculator. Higher resolutions also need more network capacity, which the IP camera bandwidth calculator estimates per camera and per switch. To turn a scene width into a megapixel figure first, see how many megapixels a security camera needs.
FAQ
How far can a 2.8mm security camera see?
It depends on resolution and what you need to see. With a 2 MP 1/2.8-inch sensor, a 2.8 mm lens reaches 25 px/m, the IEC 62676-4 detection level, out to about 127 ft (38.6 m), but identification at 250 px/m only out to about 13 ft (3.9 m). The AXIS P1385 datasheet lists 38.8 m and 3.9 m for the same sensor at 2.8 mm.
Is a 2.8mm or 4mm lens better for a security camera?
A 2.8 mm lens covers a wider area (about 90° on a 1/2.8-inch sensor), while a 4 mm lens covers about 70° but keeps the same pixel density about 43% farther away. Choose 2.8 mm for wide, close areas such as a porch or yard, and 4 mm or longer for a driveway or entrance where you need to recognize faces.
What do detect, observe, recognize, and identify mean?
They are the operational requirements from IEC 62676-4, summarized as DORI. Detection means you can tell a person is present; observation shows characteristic details such as clothing; recognition lets a viewer tell whether a person is someone seen before; identification means the person can be identified. Per Axis, they need 25, 63, 125, and 250 px/m.
Does a higher resolution camera see farther?
Yes, if the sensor size and lens stay the same. On a 1/2.8-inch sensor with the same lens, a 4K (3840 px) camera has twice the horizontal pixels of a 2 MP (1920 px) camera across the same field of view, so every DORI distance doubles.
Is DORI still part of IEC 62676-4?
The 2014 edition uses detection, observation, recognition, and identification. Axis reports that IEC 62676-4:2025 replaces these terms with seven levels, from Overview (20 px/m) to Scrutinize (1500 px/m). Many datasheets still list DORI distances, which is why this chart uses them.
Sources
- Axis Communications: Pixel density based on IEC 62676-4:2014 (white paper)
- Axis Communications: Pixel density based on IEC 62676-4:2025 (white paper)
- Sony Semiconductor Solutions: IMX327LQR/LQR1 product flyer (Type 1/2.8, 2.9 µm, 1920 × 1080)
- Sony Semiconductor Solutions: IMX335LLN/LQN product flyer (Type 1/2.8, 2.0 µm, 2592 × 1944)
- Sony Semiconductor Solutions: IMX415-AAQR product flyer (Type 1/2.8, 1.45 µm, 3840 × 2160)
- Axis Communications: AXIS P1385 Box Camera datasheet (DORI distances)
Choose the right resolution too.
See how 2 MP, 4 MP, 5 MP, and 4K cameras compare.
Compare Resolutions